Filter Results By:

Products

Applications

Manufacturers

Showing results: 316 - 330 of 337 items found.

  • Bidirectional DC Power Supply + Regenerative Load

    62000D - Chroma Systems Solutions, Inc.

    Chroma 62000D programmable bidirectional DC power supplies have both power source and load characteristics, two quadrant operation, and allows feedback of the power from the DUT. They can be used for testing renewable energy power systems including PV/storage hybrid inverters, power conversion system (PCS) on charging/discharging, and as a battery simulator. The 62000D also is a fit for testing power components used in electric vehicles, such as bidirectional on-board chargers (BOBC), bidirectional DC convertors, and DC-AC motor drivers, and power conversion simulation tests of batteries in both directions.

  • HIPOT Insulation Testers

    Laycock Systems

    Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages; 500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Standard Series - IBEKO Power AB

    When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.

  • 1000A AC Clamp Meter with IR Thermometer

    Extech EX810 - Extech Instruments Corporation

    The EX810 Clamp meter features a built-in IR thermometer with laser pointer for non-contact surface measurements from -58 to 518 degrees Fahrenheit (-50 to 270 degrees Celsius). Clamp measures AC current up to 1000 Amp with a maximum resolution of 0.1 Amp. The 1.7 in. jaw fits around conductors up to 750MCM. Peak hold captures motor inrush currents and other surges. Data hold and auto power off functions. Other features include AC/DC voltage, resistance, capacitance and frequency. Complete with test leads, 9 Volt battery and case.

  • 400A Dual Input AC/DC Clamp Meter + NCV + IR Thermometer

    Extech EX623 - Extech Instruments Corporation

    This TRMS AC/DC Clamp Meter has dual thermocouple inputs for T1, T2, T1-T2 Differential Temperature measurement plus a built-in Infrared Thermometer with laser pointer for locating hot spots and NCV Detector. Additional features include: DC micro-amp function for flame rod measurements, Diode open circuit voltage of 2.8 Volt, Data Hold plus fast Peak Hold for capturing current surges at motor startup, and capacitance measurement to 40mF. Comes complete with test leads, 9 Volt battery, two Type K bead wire Temperature probes and carrying case.

  • Automated Test Equipment

    ATE - Frontier Electronic Systems Corp.

    The design, development, manufacture and integration of Automated Test Equipment (ATE) systems is a core technology focus for FES. Our engineers have designed and manufactured complex flight line test systems for military aircraft such as the F-15, F-18, C-17, B-1, B-52 and OV-22 aircraft. In 1994, FES developed the Common Core Test Set to test space systems electronics for the Defense Support Program (DSP). This open-architecture, high-reliability electronics test set has been upgraded over the last 20 years with new hardware and graphics-based software to accommodate the complex testing requirements associated with the International Space Station Rotary Joint Motor Controller and other satellite electronics. Maritime ATE systems designed and manufactured by FES include Radar & Video Distribution factory test systems supporting US and Canadian Navy customer production requirements. Core components of FES-developed ATE systems include the use of PXI/PCI/VXI/VME technologies, National Instruments Test Stand software, Agilent Technologies instrumentation, and Virginia Panel interface hardware. The FES ATE design team employs CMMI level 3 compliant processes throughout the design process from Systems Requirements Analysis through verification and validation of ATE compliance with customer hardware, software, and documentation requirements.

  • 1000A True RMS AC/DC Clamp Meter with IR Thermometer

    Extech EX830 - Extech Instruments Corporation

    The EX830 clamp meter features a unique, built-in, non-contact Infrared thermometer with laser pointer to monitor temperature and locate hot spots on motors and electrical devices. A large 4000 count LCD display with bright back lighting allows you to see the reading in dim light. The ergonomically designed double-molded housing offers a better grip for one-hand operation. The 1.7" (43 mm) diameter jaw opening is large enough for conductors up to 750MCM. In addition to AC/DC current, it measures AC/DC voltage, resistance, temperature, capacitance, and frequency. It features: diode test, audible continuity beeper, min/max, data hold, auto power off, and a fast peak hold that captures inrush currents and transients. Comes complete with test leads, 9V battery, type K bead wire temperature probe (-4 to 482°F/-20 to 250°C) and a belt holster.

  • Resistors

    Vishay Intertechnology, Inc.

    A passive two-terminal electrical component that implements electrical resistance as a circuit element. In electronic circuits, resistors are used to reduce current flow, adjust signal levels, to divide voltages, bias active elements, and terminate transmission lines, among other uses. High-power resistors that can dissipate many watts of electrical power as heat may be used as part of motor controls, in power distribution systems, or as test loads for generators. Fixed resistors have resistances that only change slightly with temperature, time or operating voltage. Variable resistors can be used to adjust circuit elements (such as a volume control or a lamp dimmer), or as sensing devices for heat, light, humidity, force, or chemical activity.

  • 1000A AC/DC True RMS Clamp/DMM + IR Thermometer

    Extech EX840 - Extech Instruments Corporation

    This CAT IV True RMS clamp meter features a built-in IR thermometer with laser pointer for non-contact surface measurements from -58 to 518 °F (-50 to 270 °C). Clamp measures AC current up to 1000 Amp with a maximum resolution of 0.1 Amp. The 1.7-inch jaw fits around conductors up to 750MCM. Peak hold captures motor inrush currents and other surges. Data hold and auto power off functions. Other functions include AC/DC Voltage, resistance, Type K thermometer, capacitance and frequency. Complete with test leads, Type K temperature probe, 9 Volt battery and case.

  • Digital Insulation Tester - Compact Insulation Resistance Tester with Snap-On Protective Cover

    Extech MG310 - Extech Instruments Corporation

    The MG310 is a Compact Insulation Resistance Tester which allows quick and easy testing/troubleshooting of motors, transducers, and other industrial appliances. Wide range measurement up to 1000V with Insulation Resistance to 5.5GΩ. Includes an easy snap on protective hard cover and soft pouch to conveniently transport your meter and accessories to the next job site or to safely store away. Featuring Low Resistance measurement with Zero function, Continuity beeper, Large 2000 count dual display with backlight, High voltage and overload indication, Auto-discharge and voltage output warning functions as well as Low battery indication. Complete with test leads, alligator clips, 6 x AA batteries, hard cover, and soft carrying case.

  • Micro-ohmmeters

    MMR-650 - Sonel S.A.

    Designed to measure very low resistances of both resistive and inductive types of objects, including amorphous core transformers. This product is made to be used in power plants, railways and maintenance companies, to measure welded and soldered connections, equipotential bondings, earthing conductors, contacts, bolted connections, windings of motors and power transformers and other resistive and inductive objects. MMR-650 can be also utilized on a production lines (eg. at the final production control stage). An innovative combination of a high-performance measuring device with a modern user interface and advanced data management system. Wireless data transmission, enhanced system of 2D codes and ability to print labels to identify test items, all contribute to bringing new quality of work and allow the user to perform a wide range of measurements.

  • Tensile Strength Tester

    Atico Export

    Capacity of Tester with accuracy of 100g : 250 Kgf. and 500 Kgf.Capacity of Tester with accuracy of 10g : 20 Kgf, 50 Kgf and 100 KgfS Type Load Cell fixed with Top GripTraverse Speed: 300 & 100mm /min.Grip Separation: 1000 mmGrip Separation: 25 mmTop Grip is fixed and Bottom Grip is Movable Type.Elongation measurement by Steel Scale and Digital Counter Meter Both.Digital Display of Load and Elongation.Peak value of last test can be read.User friendly key panel with switch of zero setting and peak value of last testMotor: 1/2 HP single phase 220V 50 Hz. ( for Capacity up to 100 Kgf )Motor: 1 HP single phase 220 V 50 Hz ( for Capacity up to 500 Kgf)Power: 220 V AC 50 Hz.Safety device by limit switch to protect from over traverse.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TD Series - IBEKO Power AB

    Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • DC Electronic Load

    Model - KM-mPD-501 - Kusam Electrical Industries Limited

    KM-mPD-501 DC electronic load mainly focuses on the testing of power circuit on PCB. KM-mPD-501 offers a solution for function test of Switch step up, Stepdown, Regulators and Driver IC . Engineer puts components, such as CPU, DSP, FPGA; etc on a PCB after the power circuit has been tested. It’s not complete to use a meter to measure the voltage. KM-mPD-501 offers engineer OVP, OCP and OPP functions that help engineer know the value of overload current . On the other hand, engineer can use a programmable DC power supply (mPP series) to offer external power and connect PCB’s output to KM-mPD-501. Then engineer can easily get output watt, figure out the efficiency of power circuit and check if inductances, capacitances and resistances perfectly work with the power circuit. KM-mPD-501 not only offers loading emulation of current but also provides OVP and OPP. User can use these functions to test solar power battery, rechargeable battery and motor driver. In school laboratory, KM-mPD-501 helps students do experiment on power circuit, linear circuit and driver circuit.

  • NI-9244, 400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module

    783106-01 - NI

    400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9244 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, industrial machinery, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9244 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta. You can incorporate the NI‑9244 into systems to meet standards such as IEC 61010‑1, C37.90 and C37.60, IEC 60255‑22‑(1:7), IEC 60255‑1, C37.188 Class M and P, EMC section of IEC 60870, EMC sections of IEC 61850, IEC 61000‑4‑30 Class S, and IEC 61000‑4‑7.

Get Help